Symphonie
Connections: 2 inputs and 2 ouputs. Max voltage input: 20 V p-p, Overload protection. Sampling: 51.2 kHz max.. PCMCIA connector.
Further product information.
Symphonie consists of one or two transducers (microphones, accelerometers or intensity probe) connected to a small acquisition unit (single or dual channel), which transfers data in real-time to a notebook computer. Symphonie has now become a reference product in the 01dB-Metravib offer. Its real-time performance allows simultaneous analyses in both time and frequency domains. Symphonie replaces at the same time the traditional measurement instruments (sound level meters, frequency analysers, digital tape recorder, intensity meters, etc.)
Key Features
A complete set of Recording and Analysis tools, data management and reporting
- Simultaneous real-time multi-analysis as: Averaged and multi-spectra with FFT and 1/1 down to 1/48 octave, cross-spectra, etc.
- Advanced software package for: Frequency Response Functions, Order analysis, Transient & Impact Testing analysis
- Customizable, with an enhanced path management for modal analysis
- Set of application oriented post-processing functions with analysis scripts
- Transducers Database management: Sensors, calibrators, calibration history,...
- Data Import: UFF58, Wave, nCODE, Matlab, ASAM/ODS, SONY, TEAC (Digital format)
- Data Export: ASCII, Wave, MeScope, Matlab, mp3, Lexade, SDF...,
- Powerful bi-directional link to Matlab and compatibility with Office software
- Automatic reporting capabilities from real-time and post-processing modules
PRO-118 Technical Specifications
Symphonie Hardware characteristics
Signal Input
- Input impedance: 1 Megohms
- Input connection: DC o AC (da 0,3 o 10 Hz +/ - 10 %); LEMO 7 pin
- Signal conditioning: Microphone Preamplifier (28V-10mA), Polarization Voltage (0-200 V), IEPE* (4.3 mA), Direct Input
- Tacho input: Auxiliary Input
- Max voltage input: 20 V p-p, Overload protection
- Channels Phase: < 0.1° with same gain on both channels, < 0.5° if different gain
- Filtering: Hi-Pass filter (0.3/10 Hz)
A/D Converters
- Resolution: 18 bits sigma/delta.
- Sampling: 51.2 kHz max.
- Antialiasing: Butterworth, 120dB/octave
- Offset: Automatic
- Signal/Noise ratio: > 90dB
- Amplifiers: up to 65 dB in 1 dB step
- Dimensions: 85 x 35 x 220 mm
- Weight: 500 gr
Analog Output
- Type: 1-2 channels output syncronized with acquisition
- Sampling: From 100 Hz to 51.2 kHz
- Connection: LEMO 4 pin
- Converters: 18 bits
- Max Voltage output: 5 V p-p
Power Supply
- Phantom referenced
- Power supply Type: PC powered PCMCIA card
Digital I/O
- Connections: 2 inputs and 2 ouputs
- Processors: TMS320C31 + TMS320C203
- Performance: 100 MFLOPS
- Precision: 32 Bits
- SRAM: 128K x 32 bits
- RAM: 16Kb double access
- Connector: Mini Dyn (PS/2 )
dBFA software suite
Main setup parameters
- Symphonie Hardware management & configuration
- Transducers and Calibrators: Database management - transducers sensitivity monitoring - calibration validity management
- Calibration validity management: Calibration check - Manual & Automatic range adjustment
Digital Recording
- Signal & RPM recording: Direct-to-disk (PC)
- Any channel can serve as a Tacho channel
- Digital Recording and Frequency/Level Monitoring done simultaneously
- Frequency Monitoring (FFT: 1024 lines,1/3 octave, RMS), Level Meter (RMS)
Real Time processing features
- Triggers: Unlimited triggers (and/or) combinations Trigger on Time, on Level, on Threshold, on Tolerance curves. All for Start/Stop conditions
- Statistics: RMS, RMS in band, Leq, Min, Max, Peak, P-P, Average, Disparity, Skew, Kurtosis, Statistics vs. time
- Narrow Band Analysis up to 12,800 lines (from 0Hz to Max Bandwidth and zoom)
- Broad Band Analysis up to 1/48th (from 0,01Hz to Max Bandwidth)
- Average FFT, Average Cross Spectrum, Average 1/n analysis
- Cross vs. Time, Octave vs. Time, FFT vs. time
- Real time Display: Bode (2D Diagram - Amplitude and Phase), Text, Sonogram (color map), Bar Graph
Post Processing features
- Measurements database: Complete measurement session in a database, Multiple databases management, Multiple selection on database items, Add Comment on Displays, Copy/Paste Picture or Data to MS office
- Import: .wav; .mp3; uff; .dac (Nsoft); .hdr (Teac); .log (Sony); Lexade
- Data export: .wav; .txt; .mp3; .uff; .m (MatLab); .blk (Me-Scope); Lexade
-
Time domain:
Time Selection, Playback, Resampling,
Decimation, Offset compensation,
Arithmetic Operations on signals
Filtering: Digital Filtering Low pass, High Pass, Band-pass, Band-cut, notch
Weighting: A, B and C acoustic weightings, Human Vibration frequency weightings,
Denoising, Convolution (Post Processing on audio signals)
Amplitude gain adjusting: Manual Gain, Automatic Optimized Gain
Windowing: Rectangular, Hanning, Hamming, Blackman-Harris, Kaiser-Bessel, Flat-top, Triangle, Exponential, Zero, Hole
- Statistics: Statistics - RMS, RMS in band, Leq, Min, Max, Peak, P-P, Average, Disparity, Skew, Kurtosis; Statistics vs. time idem as above
- Frequency Analysis:
FFT (up to 12,800 Lines),
1/n (up to 1/48th Oct.),
Auto and Cross Autocorrelation,
Echogram,
Cross Spectrum, Transfer Functions (Inverse and Direct FRF),
Coherence,
Overall Level
Time-Frequency,
Operation on spectra...
- Display: Bode (2D- Diagram), Sonogram view, Lissajou, Waterfall, Simple cursor, Double, Harmonics, Sidebands Cursors, Energy calculation between 2 cursors and user-defined bandwidth, Automatic Peak(s) Search, Nichols/Nyquist
- Units: RMS, PWR, PSD, ASD, ESD
- Automation: Matlab communicator, processing Shortcuts, Batch Analysis