Datalogger for current, voltage and binary signal

Data loggers are designed for record of voltage signal 0-5V (optionally 0-10V) or current signal 0-20mA. At the same time state of binary signal can be recorded.

Further product information.

  • included traceable calibration certificate from the manufacturer - Comet
  • fast data transfer to the PC (full memory for approximately 30s)
  • variability of connection to the computer - USB, RS232, Ethernet, GSM modem
  • permanent connection to the PC enabled, data is possible to download even during logging
  • large data memory 32000 values
  • large dual line display with special symbols, switchable
  • optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
  • dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display
  • two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared)
  • robust watertight case
  • easy installation, locking enabled
  • low power consumption from battery, battery life up to 6 years
  • indication of remaining battery life, easy replacement of the battery
  • logging start/stop is enabled: at certain time and date programmed from computer, by external binary signal or by delivered magnet
  • also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
  • input signal is recalculated and displayed in real measured physical units by means of the PC software
  • each logger is possible to describe with text of maximum 32 characters
  • each channel is possible to describe with text of maximum 16 characters
  • password protection is enabled to prevent unauthorized manipulation with logger

Typ LOGGERY S DISPLEJEM Rozsah měření
S5011 Single channel voltage data logger 0-5Vdc + binary signal
(0-10Vdc available as an option)
S5021 Dual channel voltage data logger. Input channels are not galvanic isolated and have common ground. 0-5Vdc + binary signal
(0-10Vdc available as an option)
S6011 Single channel current data logger. The current loop should be powered from external power supply. 0-20mA + binary signal
S6021 Dual channel current data logger. The current loops should be powered from external power supply. Input channels are not galvanic isolated and have common ground. 0-20mA + binary signal