Datalogger for current, voltage and binary signal
Data loggers are designed for record of voltage signal 0-5V (optionally 0-10V) or current signal 0-20mA. At the same time state of binary signal can be recorded.
Further product information.
- included traceable calibration certificate from the manufacturer - Comet
- fast data transfer to the PC (full memory for approximately 30s)
- variability of connection to the computer - USB, RS232, Ethernet, GSM modem
- permanent connection to the PC enabled, data is possible to download even during logging
- large data memory 32000 values
- large dual line display with special symbols, switchable
- optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display
- two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared)
- robust watertight case
- easy installation, locking enabled
- low power consumption from battery, battery life up to 6 years
- indication of remaining battery life, easy replacement of the battery
- logging start/stop is enabled: at certain time and date programmed from computer, by external binary signal or by delivered magnet
- also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- input signal is recalculated and displayed in real measured physical units by means of the PC software
- each logger is possible to describe with text of maximum 32 characters
- each channel is possible to describe with text of maximum 16 characters
- password protection is enabled to prevent unauthorized manipulation with logger
| Typ | LOGGERY S DISPLEJEM | Rozsah měření |
| S5011 | Single channel voltage data logger | 0-5Vdc + binary signal (0-10Vdc available as an option) |
| S5021 | Dual channel voltage data logger. Input channels are not galvanic isolated and have common ground. | 0-5Vdc + binary signal (0-10Vdc available as an option) |
| S6011 | Single channel current data logger. The current loop should be powered from external power supply. | 0-20mA + binary signal |
| S6021 | Dual channel current data logger. The current loops should be powered from external power supply. Input channels are not galvanic isolated and have common ground. | 0-20mA + binary signal |